Sign In | Join Free | My polstate.com |
|
Brand Name : Wayeal
Model Number : LC3200
Certification : ISO, CE
Place of Origin : Anhui, China
MOQ : 1
Price : Negotiation
Payment Terms : L/C, T/T
Supply Ability : 50pcs/month
Delivery Time : 30 days
Packaging Details : Wooden Case
Product Name : Liquid Chromatography Instrument
Detector : UVD/ELSD/DAD/FLD/RID
Working Power Supply : 220V, 50Hz
Ambient Temperature : 10-40°C
Relative Humidity : 20~85%
Qualitative Repeatability : ≤0.2%
HPLC Cromatografía High Performance Liquid Chromatography Instrument for Aflatoxin Analysis
Description of High Performance Liquid Chromatography Instrument
HPLC is an analytical chemistry technique applied to separate, identify, and quantify semi- and non-volatile compounds in liquid samples. Industries like pharma and biopharma, environmental, and food and beverage use HPLC for the characterization, purification, and quantitation of compounds. An HPLC instrument has four major components: a pump to deliver the mobile phase, an autosampler to inject the sample, a stationary phase column to separate the sample compounds, and a detector to measure the compounds. Additional elements include connective capillaries and tubing to allow the continuous flow of the mobile phase and sample through the system and a CDS package to control the HPLC instrument, separation, detection, and result evaluation.
Technical Data of High Performance Liquid Chromatography Instrument
HPLC Cromatografía High Performance Liquid Chromatography Instrument for Aflatoxin Analysis | |
Working Conditions | |
Working Power Supply | 220V,50Hz |
Ambient Temperature | 10-40℃ |
Ambient Humidity | 20-85% relative humidity(non-condensing) |
System features | |
Qualitative Repeatability | RSD≤0.2% |
Quantitative Repeatability | RSD≤0.4% |
High Pressure Pump | |
Flow Rate Range | 0.0001-10.000mL/min( increments: 0.0001mL/min) |
Setting Step | 0.001mL/min |
Pressure Range | 0~42MPa |
Pressure Pulsation | 0.1MPa(10MPa, C18, methanol 1mL/min) |
Flow Rate Set Error | ±0.2% |
Flow Rate Set Stability | RSD≤0.06% |
Gradient Error | ±1% |
Column Oven | |
Temperature Control Range | 4~85°C |
Temperature Stability | ±0.02°C |
Temperature Setting Resolution | 0.1°C |
Autosampler | |
Injection Volume Repeatability | <0.5%RSD |
Linearity | >0.9999 |
Injected Volume Accuracy Error | ±1% |
Cross Contamination | <0.002% |
Number of Smaples | 120(2*20,2mL) |
Injection Volume | 1-100μL |
Application of High Performance Liquid Chromatogaphy Instrument
Determination of furadan, atrazine, glyphosate, deltamethrin, metofenpropathrin, cyfluthrin, cyfluthrin, cyhalothrin in drinking water.
![]() |
HPLC High Performance Liquid Chromatography Instrument For Aflatoxin Analysis Images |